This website uses cookies
More information
Navigate directly to favourite company, aircraft and sector pages with our tracker feature.

PRESS RELEASE
Issued by:

Voltage Spike requirement for A350XWB
Monday, 8 September 2008

Variable frequency generators are driving new test requirements for the A400M and A350XWB. Airbus specification AMD-24C has now been incorporated into the specification ABD0100.1.8. The EMC PARTNER solution is a "plug and play" module for the already popular MIG2000-6 test system. The new module (Fx-AMD-24C) generates 2/10us, 2/50us, 2/100us, 2/200us and 2/400us impulses. Together with the inductive coupling clamp CN-MIG-BT4, these can be superimposed on to AC or DC power lines either individually or simultaneously. A new de-coupling network DC- S17CL is needed to maintain high enough impedance on the line being tested so that the specified impulse reaches the unit under test.

Contact details from our directory:
EMC Partner AG Test Equipment, Environmental Test Equipment, Laboratory Equipment, Cable Test Equipment, Signal Generator Test Equipment